Valve installation may seem simple, but in reality, any negligence in details can easily lead to problems.


    Taboo 1: Not conducting a visual inspection before installation

    Consequences: The valve body exhibits sand holes and cracks, and the flange was misaligned during transportation, leading to leakage upon direct installation.


    Correct practice: Inspect the valve casing one by one before installation, verifying the model, pressure rating, and material.



    Taboo 2: Not cleaning the valve

    Consequences: Residual casting sand, grease, or debris trapped between valve discs can enter the pipeline, causing damage to the pump body or blocking the instrument.


    Correct practice: Before installation, remove the rust-preventative oil and dirt from the sealing surface of the valve port (unless there are special lubrication requirements in the design).



    Taboo 3: Uneven stress distribution during tightening of flange bolts

    Consequence: The flange is subjected to unilateral stress, resulting in misalignment of the gasket or fracture of the flange.


    Correct approach: Symmetrical, uniform, and tightened in multiple stages.



    Taboo 4: Installing without considering the flow direction of the medium

    Consequences: For globe valves and check valves, installing them upside down can lead to significant flow resistance, and a malfunctioning check valve can result in water hammer.


    Correct practice: Strictly adhere to the direction indicated by the arrow on the valve body

     

    Taboo 5: Ignoring the installation environment space

    Consequence: The valve handwheel is pressed against the wall, making it impossible to fully open or close; there is no space to tighten the flange bolts.


    Correct approach: Reserve sufficient space for operation and maintenance.



    Taboo 6: Forcing a match

    Consequence: Misalignment of the pipeline, forced connection with a valve, resulting in the valve body bearing pipeline stress and the shell cracking.

    Correct approach: Precise pipeline prefabrication is essential, and the pipelines on both ends of the valve should align naturally.


    Taboo 7: Improper selection of gaskets or reuse of old gaskets

    Consequence: Gasket failure under high temperature and high pressure, or corrosion medium penetrating through the gasket.

    Correct approach: Select the appropriate gasket based on the medium and temperature, and replace the gasket with a new one after cleaning the flange sealing surface.


    Taboo 8: No degreasing treatment for cryogenic valves

    Consequences: Under oxygen-rich or low temperature conditions, oil contamination may spontaneously ignite or freeze, causing the valve to jam.

    Correct practice: The oxygen pipeline and cryogenic valves must be strictly degreased.


    Taboo 9: The installation location places the operator in a dangerous area

    Consequences: The steam valve outlet is facing the operating aisle; there is no operating platform for the high-altitude valve.

    Correct practice: The direction of the handwheel should be convenient for operation, avoiding directing the splashing of high-temperature medium towards the sidewalk.


    Taboo 10: The discharge port of the safety valve faces the sidewalk or equipment

    Consequence: Injury caused by the ejection of high-temperature and high-pressure medium during takeoff.

    Correct practice: The safety discharge outlet should be led to a safe location.

     

    Taboo 11: Using a handwheel or handle as a lifting point

    Consequences: Deformation of the handwheel, bending of the valve stem, and packing leakage.

    Correct method: When lifting, the valve body or flange neck should be bundled.


    Taboo 12: Valves are left in a slightly open state all year round (except for regulating valves)

    Consequence: The medium erodes the sealing surface over a long period of time, causing damage and resulting in a leaky seal when closed.

    Correct practice: Gate valves and globe valves should either be fully opened or fully closed (regulating valves are required for regulating conditions).


    Taboo 13: No switch markings for rising stem gate valves

    Consequence: It is difficult to determine the actual position of the valve plate based on the position of the valve stem, especially for buried or overhead valves.

    Correct practice: Make good marks for opening/closing limits.


    Taboo 14: Working outdoors for extended periods without proper protection

    Consequences: Rusted valve stem threads, aged packing, and frozen and cracked valve body due to water accumulation in winter.

    Correct practice: Important valves should be equipped with rain covers, and the valve stems should be regularly lubricated.